Problem

Small, light mouldings can stick to the face of the tool due to static charge. This can result in mould damage and slower production speeds.

Solution

A Meech Model 957 Ionising Air Curtain positioned either above or to the side of the problem area will neutralise the static charge and help remove the parts. Air may be pulsed through the air curtain only when the tool opens to save on air and stop unwanted cooling of the mould tool.

A Meech Model 935 ionising blower or model 971 Pulsed DC Bar positioned above the collection bucket will stop static charges being regenerated.

Application Sheet

824: Drawing of Mouldings Sticking To Tool Face During Injection Moulding