변환 중
Contamination removal in converting industry
The converting process industry covers a wide range of applications, materials, and product widths. Predominantly handling thin calliper materials in roll-to-roll, or sheet-to-sheet formats, the converting process covers unwinding, sheeting, extruding, coating, drying, calendaring, laminating, delaminating, die cutting, laser cutting, slitting, printing, packaging, winding, and many more.
Frequently used web materials are papers, foils, plastic films woven and non-woven textiles. Process speeds can be slow for very intricate conversion processes but are frequently at high speeds to maximise productivity and profitability.
Processes can be on a large industrial scale, or small scale at a single end user but in both cases a large amount of power and control is needed to drive the machinery and process performance.
From its raw material form the different processes convert and add value to an enhanced product in roll or sheet form (to pass onto another production stage), or to the final product at the end of the line.
High speed material transfers often lead to static charge build up resulting in material misbehaviour on machine, ink laydown problems, and contamination attraction (from processes or environment). If not controlled process speeds become limited or changes in conditions require speeds and productivity to be reduced.
Surface contamination can become embedded affecting coating and print quality resulting in down stream product performance or poor presentation.
The high level of automation and control equipment requires high power draw and significant amounts of cooling solutions for standard operating or high seasonal peak temperatures.
With an unrivalled range of static control, static generation, sensors and datalogging, non-contact and contact type web cleaning, air-efficiency and air-cooling systems, Meech delivers a suite of cost saving solutions into the converting industry which enhances productivity, maximises yields and supports customers with the latest industry offerings to get the work done.
당사의 제로 결함 전진 접근 방식
We have identified a number of applications within the converting industry that are prone to contamination on the line. By applying the right solutions at these points, you make sure there are no weak links to your production chain. We explore these below and demonstrate our solutions…
Converting supply applications
It is critical that static electricity is controlled during converting applications. Below are some of the main areas affected by static charges during production, and our solutions to remove static charges and other contaminants:
ESD & Contamination Control On Re-winders with Lay-On Rollers
문제 :
Very high static charges are generated on the plastic web during the unwinding and rewinding process. This can cause various problems for converters and their customers, such as:
- Unpleasant shocks to operators
- Dust attraction, leading to contaminated stock
- Poor quality wound reels which can be difficult to fit onto machines and may cause feed problems
- Structural damage to coatings
- Exposing edges to damage – incorrect tension causing core crushing or core drop out
해결 방법 :
The most effective solution to overcome these issues would be through the use of the Meech 924IPS bar, situated in the position shown.
The positioning of a Model 924IPS bar at the unwind will provide control of static charges.
However, depending on the direction of the wind, clockwise will neutralize both sides of the material. When rewinding anti-clockwise the bar will only be facing one side of the material. Due to the constant 30mm distance, combined with the powerful ionization produced by the 924IPS bar, any residual charges will be minimal on the rewound roll.
Static Control During Film Rewinding
문제 :
Winding up film on extruded or blown film lines produces high levels of static electricity, often in excess of 200 kV. This can lead to a number of major problems:
- Operators can receive painful and unpleasant shocks
- High levels of static in the reel can cause production problems for the customer
- Dust can be attracted from up to 1 metre away, leading to contamination of the film.
해결 방법 :
The correct selection of equipment will be driven by the design of machine, space constraints etc. The model 935 fan driven ionised air blower delivers a high volume of concentrated ionised air to the wind on. The gentle flow of ionised air spreads from the blower head to give wide coverage as well as long range neutralisation. Long range ionisation ensures neutralisation of the entire film roll. Fan filters are available to ensure that only clean air is projected at the film.
To avoid the imprinting of any contamination from the roller itself to the substrate coating we suggest the use of either our CyClean-R which is ideal for use on a roller, or our contact RoClean. This will effectively clean the roller of any contamination to ensure there is no transmission to the web.
Static Control During Ink Jet Printing Preventing Misting, Dripping & Print Head Blockages
문제 :
Wide format digital printing has problems when printing onto insulative materials, resulting in poor print quality, print head blockages, ink drips (tagging) misting and poorly defined print edges. Electrostatic charges generated by the removal of protective films, and drying of the ink between passes repels the ink, preventing laydown. Small atomised ink particles are repelled by the electrostatic charges on substrate causing an ink cloud. This ink will collect and build up on the print head or will settle on the substrate in the incorrect position as a mist producing poor print clarity.
The ink which collects on the print head will pool before dripping into the substrate, resulting in the print being rejected. A worse problem will be the ink drying onto the print head blocking the jets. This can and does result in replacement of the print heads.
해결 방법 :
The installation of a Meech 976 Mini Pulsed DC system will provide the ultimate solution to all of these problems. As a light weight compact electrostatic control system, it; –
- Limits the additional weight on the print carriage, when compared to an AC system.
- Enables higher print quality when compared to a comparative AC system.
- Reduces the press down time for head maintenance.
- Prevents scrapping product due to ink drips.
- Reduces the risk of expensive head replacements.
During this stage, the web and coating layers are compressed together to the correct thickness, activating the coating on the web itself. Cleaning the web prior to this critical stage prevents contamination being trapped between the layers themselves.
Preventing Damage Or Weakening Of RFID Tags Due To ESD
문제 :
The application of RFID tags to an adhesive web prior to laminating can result in the generation of electrostatic charges high enough to destroy or weaken the chip in the tag. Failure to control these charges can result in field failures and loss of product and production.
해결 방법 :
The adhesive web needs to be kept free of electrostatic charge during the transfer of the tag. The removal of the tag from the paper carrier will generate high levels of electrostatic charge. Installing a Meech 261 flexi nozzle to trickle feed air over the RFID tag as it separates from the paper carrier can allow the air flow to be utilised to produce a down force, helping adhere the label in place while neutralising the electrostatic charges. Mounting a Meech 971 bar (1) under the web path can control the electrostatic charge on the web during transfer and rewinding, while a second 971 bar (2) will be required to neutralise the lamination prior to being applied to the RFID tags and web.
ESD Damage Or Weakening Of RFID Tags During Die Cutting
문제 :
RFID tags are received on a reel, unwound and guillotined prior to application on to the product. The tags are easily spoilt by static discharges and require good static control during processing
Static charges generated through the un-wind can exceed the tolerance levels on RFID or security tags and can cause the following associated problems:
- Static charges blowing the RFID chip and rendering it useless
- Operators receiving unpleasant shocks
- Attraction of dust and other airborne contaminants.
해결 방법 :
A model 971 and 977CM aimed at the nip of the unwind and rewind rolls will bathe the reel in ionised air, neutralising any static charge on the reels will prevent electrostatic discharges resulting in EMP and damage to the chip. Further neutralisation will be required during the separation of the guillotine. This needs to be implemented by using Meech 261 flexi nozzles to blow ionised air into the die to neutralise it.
Narrow Web Label Ink Jet Printing and Laser Die Cutting
문제 :
Spartanics NW140 UV InkJet Label Printing and die cutting machine.
웹의 먼지 입자와 정전기는 기계에 인쇄된 라벨의 전반적인 인쇄 품질에 심각한 영향을 미칩니다.
The machine has a combination of Inkjet printing and laser cutting capabilities and utilises multifarious substrates, such as Paper , Vinyl, PP, PE, Metalized films etc, dust and surface contamination creates print related defects and static charges cause poor print and register issues.
해결 방법 :
Installation of TakClean Contact Web Cleaning System into the press after the unwind and immediately before the print section removes contamination and with the inbuilt static elimination system ensures a static free web, thus improving overall print quality.
The slitting process can cause a lot of debris which can contaminate the coated web substrate. The use of a web cleaner at this stage ensures that the particles are removed from the surface of the web and filtered away from the operating atmosphere to avoid re-contamination. With such a high risk of contamination at this stage, cleaning is imperative to avoid the risk of future electrical shortages and expensive rejects.
Static Problems Caused During Stacking Of Shingled Sheets On A Sheeting Machine
문제 :
When delivering single or shingled (overlapped) sheets onto either a conveyor or a stack, static causes the sheets to cling together resulting in collating problems. The problem is more pronounced on shingle type delivery systems. It is important that the static charges are eliminated from the individual sheets.
해결 방법 :
Single or multiple 261 DC ionizing nozzles with a flexible air output nozzle can be positioned in such a way that the ionized air produced via the 261 flows between the sheets during the delivery process. Model 915 bars positioned as shown ensure full and effective neutralisation of static charges across the full sheet width.
The 261 flexible nozzles can be positioned either below the conveyor roller or at the side of the sheets. The flexible nozzle can easily be adjusted to suit the machine. This allows the 261 nozzle to be installed in positions that would not normally be possible with alternative types of static elimination system.
Wrapping & Contamination Problems With Bottle Overwrapper Machine
문제 :
There are 3 areas of concern with this type of packaging machine:
- Dust Attraction during unwinding web
- Electrostatic attraction of web to cutting knife and vacuum transfer belt
- Electrostatic attraction of sheet to itself during overwrapping
해결 방법 :
- A Meech 935 ionising blower is used to control charges on both unwinding rolls
- A Meech 915 bar neautralises the charges on the web prior to entry to the sheeting knife area
- A Meech 971 bar is used to prevent electrostatic charges from causing sheets to be pulled out from under the containers being wrapped.
Static Problems With Wicketing Machine Bagging Lines
문제 :
During the bag making process, there are many problems caused by static charges, or aided by applying a static charge.
영역 1 :
- Static charges generated by the unwinding material will attract contamination to the material. This has a major impact for food packaging.
- The web is then folded over the “A” frame trapping static charges inside the two layers.
영역 2 :
- The addition of a gusset to the bag: the material needs to be held in place to prevent the gusset from moving out of alignment.
- Where a reinforcing strip of plastic is required to strengthen the handle section of the bag, this needs to be held in position.
- The punching of a handle through the material can cause the bag to open and stick to the punch.
영역 3 :
- Static charges on the material entering the sealing and cutting process will cause the material to stick to rollers and fail to feed onto the wicketing conveyor belts.
영역 4 :
- Static charges on the bags being placed onto the pegs will cause the bags to push apart and not hang vertically. This will result in the bags being pulled off the pegs by the wicketing arms.
- Not controlling the static charges through the production process, will cause customer issues as the bags will fail to open properly.
- High static charges on the single bags cause a major problem at the bag collating area, especially on high-speed machines.
해결 방법 :
Many antistatic systems have been evaluated in this application. Although adequate for slow machines, they are not fully effective on the newer high-speed machines. To allow maximum efficiency the recommended static control system below will optimise the production process:
영역 1 :
- The use of a long-range ionising bar such as the 971-30 kV Pulsed DC bar will prevent the attraction of contamination to the material.
- Using a 924IPS bar prior to folding ensures the charges are removed from the inside face of the web, reducing the impact of static on the finished product.
영역 2 :
- Applying a static charge, using a 993R bar and generator, to bond only the gusset in position, will prevent material movement and alignment issues.
- Applying a static charge, using a 993R bar and generator, to the web and the reinforcing strip will temporarily lock the two layers into position prior to being heat welded together.
- Applying a static charge, using a 993R bar and generator, to the top edge of the web temporarily bonds the material together, preventing the punch from separating the layers.
영역 3 :
- The compact size of the 914 AC bars allows high powered ionisation to be delivered, removing static charges that have been generated during the production process.
영역 4 :
- Two Meech 971IPS bars are required during the wicketing process. The first bar removes charges from the bags as they pass on the wicketing arms. The second uses a small quantity of compressed air, blowing ionisation continuously over the bags on the pegs, preventing charges being regenerated during the application of the next bag onto the pegs.
At the winding process we suggest a number of solutions for the best results. Prior to winding, surface cleaning of the substrate is recommended to not trap contamination within the battery film wind. To overcome static issues, which can be both dangerous and extremely detrimental to the battery performance, effective static control should also be introduced. This will neutralise any static charges caused by the winding process.
* 모든 그림은 설명 목적으로만 사용됩니다. 귀하의 공정에 가장 적합한 정전기 제어 및 웹 청소 솔루션의 위치는 귀하의 응용 분야의 특정 요소에 따라 달라집니다.
웹 클리닝 솔루션
Meech는 포괄적인 4가지 시스템을 갖춘 선도적인 웹 클리닝 제조업체입니다. 각 시스템은 서로 다른 세척 원리를 기반으로 하며, 이를 통해 당사는 고객의 용도에 가장 적합한 시스템을 제공할 수 있습니다. 모든 Meech 시스템에는 최신 충격 방지 장치가 포함되어 있습니다. AC 정적 제어 바 이는 포괄적인 오염 제거에 중요한 표준입니다. Meech는 포장, 인쇄 및 변환을 포함한 다양한 산업 분야에서 200개 이상의 성공적인 웹 클리닝 설치를 보유하고 있습니다.
Meech CyClean™은 소형, 고성능, 비접촉 웹 클리너에 대한 수요에 부응하여 설계되었습니다.
CyClean은 첨단 전산유체역학을 적용하여 1미크론 미만의 오염물질을 제거하고 추출합니다.
CyClean-R은 저압 웹 클리닝을 위한 특수 솔루션을 제공합니다.
CyClean-R은 웹 장력이 가장 높은 롤러에 위치하도록 설계되어 장력이 낮은 문제를 우회하면서도 우수한 표면 청소 기능을 제공합니다.
RoClean은 배터리 필름 제조 산업에 탁월한 표면 청소 결과를 제공하는 최신 접촉식 웹 클리너입니다.
RoClean은 정전기 제어와 효율적인 강모 롤러 브러시를 모두 사용하여 웹 표면을 효과적으로 청소합니다.
Meech 웹 클리너에는 Meech 공기조화장치(AHU)가 함께 제공되어 공기 균형을 유지하여 공기압과 진공의 정확성을 완벽하게 제어합니다. 이는 컴팩트한 산업용 사양 장치이며 PLC 제어를 통해 성능을 모니터링할 수도 있습니다.
정적 제어 솔루션
Meech는 1960년대부터 정적 제어 제품을 제조 및 공급하는 시장 선두업체입니다. 정전기 방지 및 ESD 보호 및 측정, 정전기 발생, 정전기 제어 및 제거 기능을 제공하는 광범위한 정전기 제품을 제공합니다.
24V DC로 구동되는 Hyperion 924IPS는 시중에서 가장 컴팩트한 펄스 DC 바입니다.
924IPS는 Meech의 ICM(이온 전류 모니터링) 기술을 갖추고 있어 바를 청소해야 할 때 로컬 및 원격 경고를 통해 성능이 유지되도록 보장합니다.
ur closed-loop feedback system takes advantage of the adjustable balance of pulsed DC ionising systems.
이 시스템은 Hyperion SmartControl과 폐쇄 루프 피드백을 위한 최대 5개의 Hyperion 이온화 제품으로 구성됩니다. SmartControl 센서에 연결되면 이온화 바의 웹 다운스트림 전압을 측정합니다.
이 측정값은 완전히 중립적인 웹을 달성하기 위해 출력 균형을 자동으로 조정하는 이온화 제품으로 피드백될 수 있습니다. 이는 항상 최고의 정적 제어를 달성하기 위해 지속적으로 측정하고 조정하는 지속적인 프로세스입니다.
모델 983v2 정적 위치 측정기는 재료의 정전기 전하를 명확하게 표시합니다. 일반 산업용으로 설계되었으며 200mm 거리에서 측정 시 +/-150kV의 넓은 측정 범위를 갖습니다.
983v2는 "연속" 또는 "피크 홀드" 모드에서 작동하여 각각 충전 수준의 변화 또는 감지된 최고 충전량의 변화를 기록할 수 있습니다. 이는 생산, 유지보수, 검사 및 품질 엔지니어가 사용하는 정전하 수준에 대한 좋은 표시를 제공하는 데 적합합니다. 983v2는 정전기가 문제가 될 수 있는 모든 재료에 사용할 수 있습니다.
SmartControl Touch는 현대 자동화 산업의 요구 사항과 Industry 4.0의 성장을 충족하여 생산성과 출력 품질을 극대화하도록 설계된 Meech의 최신 혁신 기술입니다.
SmartControl Touch를 사용하면 사용자는 통합 터치스크린을 통해 또는 원격으로 연결된 여러 Hyperion 이온화 바와 센서의 성능을 모니터링, 제어 및 조정할 수 있습니다.