20 metres of cable is the maximum for the 261 DC ionising nozzle.
With an 8-way splitter and a dual output power supply such as the PulseDrive Plus a total of 16 nozzles can be connected to make one system.
However, if you require more nozzles, SmartControl Touch could also be a consideration powering up to 30 devices to one system. For more guidance, please contact your local Meech distributor or contact Meech directly.
Yes, all our Pulsed DC Controllers are compatible with the 261v2 nozzles. The right DC Controller will depend on factors such as: environment, power requirement, cost and personal preferences.
No, our 261 nozzles are not currently ATEX approved, they are infact suitable for industrial and cleanroom environments and meet OSHA dead-end pressure requirements.
The 935 and 936 ionising blowers offer the same effective long-range ionisation over a large area, the only difference being the 936 features the 924IPS DC ionising bar compared to that of the 915 AC in the old 935 blower.
This enhancement adds great benefits to the new 936, such as adjustable outputs, no bulky power supplies, and a favoured M8 24V DC connection.
The maximum air pressure you can use on a 261 nozzle is 7 bar (100 Psi), but typical air pressure of 1.5 to 3 bar (20 to 40 Psi) is recommended for normal operation.
No, you cannot use metal fittings on the outlet of a 261 due to the metal acting as an earthing potential.
Yes, metal fittings are okay for use on the inlet as it will be a sufficient distance away from the emitter pins and not hinder performance.