Hyperion 314IPS Hygienic Ionising Bar

Product Code: 314IPS

The 314IPS is a compact pulsed DC ionising bar specifically designed for use in hygienic applications. Its PTFE construction is ideally suited to use on Hygienic food and pharmaceutical machinery. It is used to control static electric charges in short range applications (20-150mm).

The smooth design minimises the risk of dirt and contamination getting trapped on the bar, and would be beneficial to industries where hygiene is critical, for example, Pharmaceutical, Medical Devices and Food Packaging.

The 314IPS is the latest innovation to Meech and is the first of its kind. The compact bar meets relevant GMP (Good Manufacturing Practice) guidelines, and also features FDA and EU compliant food-contact materials.

  Download  
Features & Benefits
Hygienic Design

Design minimises risk of dirt and contamination getting trapped on the bar. Its PTFE construction is ideally suited to use on Hygienic food and pharmaceutical machinery.  Materials used are also FDA and EU food-contact compliant.

Low Voltage Wiring

The 314IPS is powered by 24V DC. To remove the potential for dirt traps, the bar is fitted with an integral 5m power cable; allowing the connection to 24V to be made in a non-hygienic area of the machine.

Adjustable Output

Performance can be optimised using the optional Hyperion BarMaster programmer or SmartControl Touch:
Adjustable balance allows fine control in sensitive applications.
Adjustable frequency allows the selection of the optimum frequency for the target distance.
Adjustable voltage for improved performance.

Shockless Titanium Emitters

The Titanium emitter pins on the 314IPS are resistively coupled to the high voltage supply. Independent research has shown titanium to be one of the very best materials for emitter pins; with extremely low wear rates. The resistive coupling built into the bar makes the pins shockless to touch, making it safe for operators to handle.

Emitter pin are also recessed to avoid contact with the pins when cleaning the bar.

IP67 Fully-Sealed Construction

IP67 fully-sealed construction allows the bar to be mounted in areas subject to wash-down or where there is the likelihood of spillages. IP67 provides total dust protection and protects from from high-pressure water jets from any direction.
Please note that should the bar become wet it must be thoroughly dried before being powered-up.

Dual Alarm Lines for Clean Pin and Fault Alerts

The 314IPS adopts the advanced alarm system of the latest Hyperion products. Dual alarm lines tell remote monitoring systems whether the ionising equipment needs routine maintenance or whether there is a more serious system failure. The flexible configuration of the alarm system, allows the alarm lines to be interfaced with PLCs, buzzers and remote lamps.

Clean Pins Alert

The local LED is solid green to indicate that the bar is on, working correctly and giving good ionisation performance. A red flashing LED shows that Meech’s Ion Current Monitoring technology has detected that the bar needs cleaning.

Fault Alert

Constant red illumination indicates that a fault has been detected on the high voltage outputs.

Technical Characteristics
Dimensions (W x H)

25mm x 38mm

Maximum Length

920mm

Weight

Weight 1.54kg/metre

Construction

Main Body and Base:
PTFE: Excellent chemical resistance, suitable for food contact (FDA & EU approval),
extremely non-adhesive and high degree of hydrophobicity.
Cable: PVC with good resistance to oil, gasoline and chemicals.
Emitters: Titanium – Excellent wear resistance.

Mountings

2 x M5 x 6mm Female Locations

Input Voltage and Current

24V DC (21-27V DC) Max 500mA

Electrical Connection

4 Pole M8 male connector, 5m length cable as standard

Output Voltage

Adjustable, +/- 3 to 7.5kV pulsed DC

Output Frequency

Default: 20Hz (Adjustable 1-99Hz with BarMaster and SmartControl Touch)
Note: Frequency settings >20Hz are only required for specialist applications. Contact Meech for information.

Output Balance

Default: 54% Positive, 46% Negative (Adjustable with BarMaster and SmartControl Touch)

Operating Range (mm)

20-150mm

IP Rating

IP67

Operating Temperature Range

-20°C – 60°C
(Max. short-term non-operating temperature 70°C)

Maximum Relative Humidity

85% RH, non-condensing

Certifications

CE

Images

Hyperion 314IPS Hygienic Ionising Bar

Product Code: 314IPS

The 314IPS is a compact pulsed DC ionising bar specifically designed for use in hygienic applications. Its PTFE construction is ideally suited to use on Hygienic food and pharmaceutical machinery. It is used to control static electric charges in short range applications (20-150mm).

The smooth design minimises the risk of dirt and contamination getting trapped on the bar, and would be beneficial to industries where hygiene is critical, for example, Pharmaceutical, Medical Devices and Food Packaging.

The 314IPS is the latest innovation to Meech and is the first of its kind. The compact bar meets relevant GMP (Good Manufacturing Practice) guidelines, and also features FDA and EU compliant food-contact materials.

 

Features & Benefits

Hygienic Design Design minimises risk of dirt and contamination getting trapped on the bar. Its PTFE construction is ideally suited to use on Hygienic food and pharmaceutical machinery.  Materials used are also FDA and EU food-contact compliant.
Low Voltage Wiring The 314IPS is powered by 24V DC. To remove the potential for dirt traps, the bar is fitted with an integral 5m power cable; allowing the connection to 24V to be made in a non-hygienic area of the machine.
Adjustable Output Performance can be optimised using the optional Hyperion BarMaster programmer or SmartControl Touch: Adjustable balance allows fine control in sensitive applications. Adjustable frequency allows the selection of the optimum frequency for the target distance. Adjustable voltage for improved performance.
Shockless Titanium Emitters The Titanium emitter pins on the 314IPS are resistively coupled to the high voltage supply. Independent research has shown titanium to be one of the very best materials for emitter pins; with extremely low wear rates. The resistive coupling built into the bar makes the pins shockless to touch, making it safe for operators to handle. Emitter pin are also recessed to avoid contact with the pins when cleaning the bar.
IP67 Fully-Sealed Construction IP67 fully-sealed construction allows the bar to be mounted in areas subject to wash-down or where there is the likelihood of spillages. IP67 provides total dust protection and protects from from high-pressure water jets from any direction. Please note that should the bar become wet it must be thoroughly dried before being powered-up.
Dual Alarm Lines for Clean Pin and Fault Alerts The 314IPS adopts the advanced alarm system of the latest Hyperion products. Dual alarm lines tell remote monitoring systems whether the ionising equipment needs routine maintenance or whether there is a more serious system failure. The flexible configuration of the alarm system, allows the alarm lines to be interfaced with PLCs, buzzers and remote lamps.
Clean Pins Alert The local LED is solid green to indicate that the bar is on, working correctly and giving good ionisation performance. A red flashing LED shows that Meech’s Ion Current Monitoring technology has detected that the bar needs cleaning.
Fault Alert Constant red illumination indicates that a fault has been detected on the high voltage outputs.

Technical Characteristics

Dimensions (W x H) 25mm x 38mm
Maximum Length 920mm
Weight Weight 1.54kg/metre
Construction Main Body and Base: PTFE: Excellent chemical resistance, suitable for food contact (FDA & EU approval), extremely non-adhesive and high degree of hydrophobicity. Cable: PVC with good resistance to oil, gasoline and chemicals. Emitters: Titanium - Excellent wear resistance.
Mountings 2 x M5 x 6mm Female Locations
Input Voltage and Current 24V DC (21-27V DC) Max 500mA
Electrical Connection 4 Pole M8 male connector, 5m length cable as standard
Output Voltage Adjustable, +/- 3 to 7.5kV pulsed DC
Output Frequency Default: 20Hz (Adjustable 1-99Hz with BarMaster and SmartControl Touch) Note: Frequency settings >20Hz are only required for specialist applications. Contact Meech for information.
Output Balance Default: 54% Positive, 46% Negative (Adjustable with BarMaster and SmartControl Touch)
Operating Range (mm) 20-150mm
IP Rating IP67
Operating Temperature Range -20°C - 60°C (Max. short-term non-operating temperature 70°C)
Maximum Relative Humidity 85% RH, non-condensing
Certifications CE