Hyperion 906 Power Unit

Product Code: A906

The Hyperion 906 Power Unit is the latest addition to Meech’s Hyperion range (superseding the 904/905), which provides the voltage required to produce ionisation for our range of AC static eliminator bars.

Traditionally, power units have an AC supply which can be susceptible to voltage fluctuations, sags, and surges. Utilising a 24VDC supply is a significant step forward in this respect, offering improved stability, reliability, and compatibility with modern control systems.

The 906 Power Unit has an adjustable (via BarMaster or SmartControl Touch) output voltage of 2-7kVAC and can power up to four bars simultaneously, making it suitable on a wide range of industrial processes and static eliminator applications.

For fast and easy connectivity, the 906 requires a 24VDC input from either a 48W switch mode or 4 pin M8 power cable (if powering directly from 24V feed).

The 906 also offers several key features detailed in the features section below. These include a unique design to allow automated manufacture for increased reliability and extended product life. To ensure a high level of operator safety, the 906 features a short circuit current of <5mA.

We also offer the 906 Power Unit in two other versions for use with products intended for hazardous locations; 906HL 5kV and 906HL 7kV. These are specifically designed for use with our 914EX and 915EX Static Eliminator bars respectively.

  Download  
Features & Benefits
Connection Ports

Power Supply for up to four AC bars simultaneously.

Adjustable Output Voltage

Adjustable output voltage (2-7kV AC) via attached BarMaster or SmartControl Touch, to suit your specific needs.

Remote Dual Alarm Signal

Remote dual alarm signal indicates when the current is low or a fault has been detected.

LED Status

Tri-Colour LED status indicator for current monitoring and fault alert.

Remote Programmers

Compatible with Meech remote programmers: BarMaster & SmartControl Touch.

24VDC Input Voltage

24VDC input voltage, favoured on modern machinery and big benefit for OEM’s.

Ion Current Monitoring

Ion Current Monitoring providing continuous monitoring of the ionising bar’s performance.

Technical Characteristics
Dimensions (LxWxH)

120mm x 130mm x 126mm

Weight

Approx 3.85kg

Maximum Ambient Temperature

55oC

Mounting

4x 6mm holes

Mounting Height

To comply with UL 62368-1, the 906 must be mounted at a height ≤2m

Enclosure

Powder coated steel

Electrical Connections

4-pin M8, earth terminal & M4 HV output post

Input Current

Maximum 2A

Input Voltage

24VDC (22 to 26VDC)

Output Ports

4x HV connection ports

Output Current

Maximum 5mA

Output Voltage
  • A906-5kV: 2 to 7kVAC (Preset to 5kV)
  • A906-7kV: 2 to 7kVAC (Preset to 7kV)
Output Frequency

70Hz

Alarm Output/Standby Input

Dual outputs for Alert/Fault monitoring (0/24V):

  • 1x Alert output
  • 1x Fault output/standby input
Alarm Output Drives

Compatible with IEC 61131-2 type 1,2,3 plc inputs

Local Indication

Green/yellow/red LED

Protection Class

IP40 construction

Certifications

CE, UL

Images
Documentation

906 Operating Manual

Download  

906 UL Certificate

Download  
Related Products
Must Haves
Switchmode Power Adaptor 48W

Product Code: A900IPS-SM2MS-48W

A 24V DC 48W Power Adaptor for use with certain products within the Meech range.

View Product

Hyperion 906 Power Unit

Product Code: A906

The Hyperion 906 Power Unit is the latest addition to Meech’s Hyperion range (superseding the 904/905), which provides the voltage required to produce ionisation for our range of AC static eliminator bars.

Traditionally, power units have an AC supply which can be susceptible to voltage fluctuations, sags, and surges. Utilising a 24VDC supply is a significant step forward in this respect, offering improved stability, reliability, and compatibility with modern control systems.

The 906 Power Unit has an adjustable (via BarMaster or SmartControl Touch) output voltage of 2-7kVAC and can power up to four bars simultaneously, making it suitable on a wide range of industrial processes and static eliminator applications.

For fast and easy connectivity, the 906 requires a 24VDC input from either a 48W switch mode or 4 pin M8 power cable (if powering directly from 24V feed).

The 906 also offers several key features detailed in the features section below. These include a unique design to allow automated manufacture for increased reliability and extended product life. To ensure a high level of operator safety, the 906 features a short circuit current of <5mA.

We also offer the 906 Power Unit in two other versions for use with products intended for hazardous locations; 906HL 5kV and 906HL 7kV. These are specifically designed for use with our 914EX and 915EX Static Eliminator bars respectively.

 

Features & Benefits

Connection Ports Power Supply for up to four AC bars simultaneously.
Adjustable Output Voltage Adjustable output voltage (2-7kV AC) via attached BarMaster or SmartControl Touch, to suit your specific needs.
Remote Dual Alarm Signal Remote dual alarm signal indicates when the current is low or a fault has been detected.
LED Status Tri-Colour LED status indicator for current monitoring and fault alert.
Remote Programmers Compatible with Meech remote programmers: BarMaster & SmartControl Touch.
24VDC Input Voltage 24VDC input voltage, favoured on modern machinery and big benefit for OEM’s.
Ion Current Monitoring Ion Current Monitoring providing continuous monitoring of the ionising bar’s performance.

Technical Characteristics

Dimensions (LxWxH) 120mm x 130mm x 126mm
Weight Approx 3.85kg
Maximum Ambient Temperature 55oC
Mounting 4x 6mm holes
Mounting Height To comply with UL 62368-1, the 906 must be mounted at a height ≤2m
Enclosure Powder coated steel
Electrical Connections 4-pin M8, earth terminal & M4 HV output post
Input Current Maximum 2A
Input Voltage 24VDC (22 to 26VDC)
Output Ports 4x HV connection ports
Output Current Maximum 5mA
Output Voltage
  • A906-5kV: 2 to 7kVAC (Preset to 5kV)
  • A906-7kV: 2 to 7kVAC (Preset to 7kV)
Output Frequency 70Hz
Alarm Output/Standby Input Dual outputs for Alert/Fault monitoring (0/24V):
  • 1x Alert output
  • 1x Fault output/standby input
Alarm Output Drives Compatible with IEC 61131-2 type 1,2,3 plc inputs
Local Indication Green/yellow/red LED
Protection Class IP40 construction
Certifications CE, UL