CyClean™ Web Cleaning System

Product Code: ACC-XXXX-XXXX-01

The CyClean Web Cleaning System comprises a double-sided web cleaning head, integrated static control equipment and an AHU (Air Handling Unit) to clean both sides of a web simultaneously to remove contamination.

Firstly, CyClean neutralises static charges and breaks the boundary layer of air that holds contamination to the surface of the web. It achieves this by using high-frequency micro-movements and turbulent airflow to shatter the boundary layer and loosen contaminants. Subsequently, the  system debris extracts the debris from the cleaning head and collects in the Air Handling Unit, which cleans and recirculates the air, resulting in contamination removal to below 1 micron.

The versatile design of the CyClean Web Cleaning System supports a wide range of variations for different applications. Options include a Narrow Web CyClean which offers either a manual opening with a unique fixed‑port design or a pneumatic opening in either end‑feed or top‑feed configurations. Additionally, a Mid Web CyClean with pneumatic opening and top and bottom (TAB) duct connections. Finally, a Wide Web CyClean with an optional end‑feed carapace configuration.

  Download  
Features & Benefits
Non Contact Cleaning

Eliminates risk of surface marking and damage. No interference with web tension or web tracking.

Compact Design

Flexible positioning & easy installation.

Integrated static control

Neutralises static charges to optimise cleaning performance and prevent re-contamination.

Unique 'fixed ports' System

The ducting connections to the cleaning head remain stationary, resulting in easier installation.

Air Balancing

Allows complete control of the bias between blowing and vacuum airflows.

Auto Airflow Adjustment

Reduces the frequency of required operator adjustments.

Hinged, Clam Shell Design

Allows unit to open for easy threading of the web.

No Consumable Items

Lower ongoing costs

Quiet Operation

Can be installed in enclosed work areas. No H&S issues due to noise.

Technical Characteristics
Maximum Web Speed (web driven)

600 mtrs/min, 1968 ft/min

Maximum Web Width

up to 2000mm, 78″

Duct Connections

Fixed position 6 x 40mm Ø OD

Static Control (active)

4 x 914 AC bars

Mounting

4 x M8 x 16mm holes

Standard Opening

Manual with gas strut and end hinges

Optional Opening

Pneumatic

Images
Videos
Documentation

Web Cleaning Overview Brochure

Download  

*Access our full library of current and archived operation manuals here.

Related Products
Must Haves
AHUv3 Mini – 1 Pump

Product Code: A-AHUV3-1PUMP

The AHUv3 Mini – 1 Pump provides the positive pressure and vacuum pressure airflows and houses the system filters.

View Product
AHUv3 Compact – 2 Pump

Product Code: A-AHUV3-2PUMP

The AHUv3 Compact provides the positive pressure and vacuum pressure airflows and houses the system filters. The AHUv3 Compact is a 2 pump unit designed predominantly for narrow web applications of up to 600mm.

View Product
AHUv3 Standard – 3 Pump or 6 Pump

Product Code: A-AHUV3-3PUMP/6PUMP

The AHUv3 provides the positive pressure and vacuum pressure airflows and houses the system filters. There are 2 models available, a 3 pump unit and a 6 pump unit. For applications where a higher volume capacity is required the 6 pump unit can be used.

View Product

CyClean™ Web Cleaning System

Product Code: ACC-XXXX-XXXX-01

The CyClean Web Cleaning System comprises a double-sided web cleaning head, integrated static control equipment and an AHU (Air Handling Unit) to clean both sides of a web simultaneously to remove contamination.

Firstly, CyClean neutralises static charges and breaks the boundary layer of air that holds contamination to the surface of the web. It achieves this by using high-frequency micro-movements and turbulent airflow to shatter the boundary layer and loosen contaminants. Subsequently, the  system debris extracts the debris from the cleaning head and collects in the Air Handling Unit, which cleans and recirculates the air, resulting in contamination removal to below 1 micron.

The versatile design of the CyClean Web Cleaning System supports a wide range of variations for different applications. Options include a Narrow Web CyClean which offers either a manual opening with a unique fixed‑port design or a pneumatic opening in either end‑feed or top‑feed configurations. Additionally, a Mid Web CyClean with pneumatic opening and top and bottom (TAB) duct connections. Finally, a Wide Web CyClean with an optional end‑feed carapace configuration.

 

Features & Benefits

Non Contact Cleaning Eliminates risk of surface marking and damage. No interference with web tension or web tracking.
Compact Design Flexible positioning & easy installation.
Integrated static control Neutralises static charges to optimise cleaning performance and prevent re-contamination.
Unique 'fixed ports' System The ducting connections to the cleaning head remain stationary, resulting in easier installation.
Air Balancing Allows complete control of the bias between blowing and vacuum airflows.
Auto Airflow Adjustment Reduces the frequency of required operator adjustments.
Hinged, Clam Shell Design Allows unit to open for easy threading of the web.
No Consumable Items Lower ongoing costs
Quiet Operation Can be installed in enclosed work areas. No H&S issues due to noise.

Technical Characteristics

Maximum Web Speed (web driven) 600 mtrs/min, 1968 ft/min
Maximum Web Width up to 2000mm, 78"
Duct Connections Fixed position 6 x 40mm Ø OD
Static Control (active) 4 x 914 AC bars
Mounting 4 x M8 x 16mm holes
Standard Opening Manual with gas strut and end hinges
Optional Opening Pneumatic